Light Transport in Tissue


Evaluation of the Delta-Eddington Approximation

This section compares solutions of the delta-Eddington approximation with accurate adding-doubling and Monte Carlo solutions. Heretofore comparisons have been for the index matched case, where the delta-Eddington approximation was found to agree with exa ct solutions for all optical depths, albedos and anisotropies [34]. This section makes comparisions for mismatched boundary conditions because of the large differences possible between fluence rates for identical tissues with different boundary conditions (cf., Figure 4.1). The following sections emphasize comparisons with an air-glass-tissue-glass-air medium. Total reflection and transmission are compared in the first subsection. This is followed by a comparision of the fluence rates for a one-dimensional slab.



S. A. Prahl."Light Transport in Tissue," PhD thesis, University of Texas at Austin, 1988.